Skip to content
BidBenchmark
Sources SoughtAmendment 2

J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |

255-NETWORK CONTRACT OFFICE 15 (36C255) · Dwight D. Eisenhower VA Medical Center 4101 S. 4th St., Leavenworth, 66048

Response status

Historical record

Aug 11, 2026, 6:00 PM UTC

This notice is no longer open.

Posted
Aug 4, 2026
Archive date
Sep 10, 2026
SAM status
Active
This is a preserved solicitation record. The response window is closed because the published deadline passed.

Answer-first brief

What the source record says

  • 255-NETWORK CONTRACT OFFICE 15 (36C255) published this sources sought.
  • The place of performance is Leavenworth.
  • The notice uses NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors).

Procurement identity

Notice ID
0998fb8dabb446df9b5f2d2d828955fc
Solicitation
36C25526Q0584
Base type
Sources Sought
Version
2 of 2

Solicitation facts

Structured fields from the current SAM notice version. A dash means the source did not publish a value.

Notice type
Sources Sought
Solicitation number
36C25526Q0584
Set-aside
Set-aside code
Posted
Aug 4, 2026
Responses due
Aug 11, 2026, 6:00 PM UTC
Archive date
Sep 10, 2026
Archive type
autocustom
Base type
Sources Sought
Organization type
OFFICE
Benchmark category
Electrical Contracting
Category confidence
94%
Category source
rule
Last seen
Aug 29, 2026

Buyer and place

Office hierarchy and place of performance as published.

Department
VETERANS AFFAIRS, DEPARTMENT OF
Department code
Subagency
VETERANS AFFAIRS, DEPARTMENT OF
Subagency code
Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Organization path
Organization path codes
Office address
LEAVENWORTH, KS, 66048, USA
Place of performance
Dwight D. Eisenhower VA Medical Center 4101 S. 4th St., Leavenworth, 66048
City code
State
State code
Postal code
66048
Country

Points of contact

Contact details from the current notice version.

Notice description

Source text reproduced without an AI summary.

Sources Sought Notice: This is not a request for formal proposals or quotes, it does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potentially qualified businesses interested in and capable of providing the required services. Documentation of technical expertise must be presented in sufficient detail for the government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone and email (e) UEI number (f) Cage Code (g) Type of small business, e.g., Services Disabled Veteran Owned Small Business, Veteran-Owned Small Business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, Small Business, or Large Business; and (h) Capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. This Sources Sought is for Dwight D. Eisenhower VA Medical Center, Leavenworth, Kansas who have a requirement for Automatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection. The NAICS Code is 238210 with a Small Business size standard of $19 million. SDVOSB/VOSB vendors must be registered in the SBA VetCert database. Offerors capable of providing this service shall notify the Contract Specialist no later than (NLT) August 11, 2026, 1:00 pm CST via email at maria.owen2@va.gov All information is to be submitted via email to: maria.owen2@va.gov. Phone calls will not be accepted. Performance Work Statement Automatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection 1. Scope The Department of Veterans Affairs requires a qualified contractor to provide all labor, materials, equipment, tools, supervision, transportation, and technical expertise necessary to perform inspections, testing, preventive maintenance, repairs, and emergency response services for Automatic Transfer Switches (ATS) and Isolation Electrical Power Panels throughout the Dwight D. Eisenhower VA Medical Center, 4101 S 4th Street, Leavenworth, KS 66048. All work shall ensure safe, reliable, and code compliant operation of all systems. 2. Period of Performance October 1, 2026 September 30, 2031 3. Performance Objectives The contractor shall deliver the following outcomes: 3.1 ATS Systems Ensure all ATS units operate safely, reliably, and in accordance with NFPA standards and manufacturer specifications. Maintain full functionality of transfer and retransfer operations, voltage sensing, phase rotation, time delay functions, and ATS battery systems. 3.2 Isolation Power Panels Ensure proper operation of Line Isolation Monitors (LIMs) and electrical isolation systems per NFPA 99. Maintain accurate, clearly labeled circuits consistent with facility electrical drawings. 3.3 Emergency Repairs Restore system functionality rapidly for critical outages with minimal disruption to clinical operations. 3.4 Compliance & Safety Ensure all work complies with NFPA 70, NFPA 70B, NFPA 99, OSHA, VA standards, and manufacturer guidelines. 4. Performance Requirements 4.1 ATS Inspection and Maintenance Tasks The contractor shall perform and document the following measurable tasks: Visual inspection with photographic evidence. Cleaning of enclosures using manufacturer approved methods. Infrared thermal scanning with image attachments. Measurement and recording of temperature and torque values using calibrated instruments. Operational testing, documenting pass/fail for: transfer retransfer voltage sensing time delay functions phase rotation ATS battery testing where applicable (voltage, load test, specific gravity). Lubrication of components using manufacturer specified lubricants. Coordinated generator functional testing, including recorded transfer and retransfer times. 4.2 Isolation Panel Inspection and Testing Requirements The contractor shall: Provide photographic documentation of panel inspections. Test LIMs, verify alarm set points, simulate faults, and document response times. Perform NFPA 99 compliant ground fault testing. Measure voltage, current, and insulation resistance values. Verify labeling accuracy against electrical drawings. Clean interiors with nonconductive tools and record methods. Verify torque values using calibrated instruments. 5. Performance Standards 6. Performance Monitoring (Government Surveillance) The COR will evaluate contractor performance using the following methods: Inspection of reports (routine & emergency) for accuracy and completeness. Random onsite inspections of ATS and isolation panel systems. Verification of corrective action timelines. Review of emergency response logs. 7. Deliverables 7.1 Routine Service Reports Due within 48 hours Reports shall include: date/time of service personnel names equipment inspected all measured values photos and thermal images pass/fail results deficiencies and recommended corrective actions references to NFPA/manufacturer standards 7.2 Emergency Repair Reports Due within 24 hours Include issue description, corrective actions, parts replaced, test results, and verification of restored operation. 7.3 Annual Executive Summary Due within 30 days Provide an overview of: system condition recurring deficiencies reliability trends recommended upgrades or corrective projects 8. Contractor Qualifications Contractor personnel shall: Maintain valid Kansas electrical licensing. Have documented experience with ATS and healthcare isolation power systems. Complete annual VA privacy, security, and safety training. Pass VA background checks (VAAR 852.237 70). Use calibrated testing instruments. Wear VA issued identification badges. 9. Security & Safety Requirements Contractor shall comply with: VA safety regulations OSHA regulations NFPA standards VA infection control procedures 10. Non Conforming Performance Failure to perform may result in: Notice of Concern Corrective Action Request Cure Notice in accordance with FAR 49.607 11. List of Equipment Automatic Transfer Switch List Type CAT # SER # CUST DESIG ASCO H07ATBB31200N5XM 1329719-WE ATS-4 122 Generator Shelter ASCO J07ATS30600C5XC 2688889-001RE Elevator ATS 88/89 SW GEAR ZENITH ZTS2L15FC-7 1402776-1 ATS-4-EHC1A 91 North ASCO J07ATBB30400N5XC 2564471-001WE ATS-B91 01 91 North ZENITH ZTS000B00060E 151048000-10-1 ATS-5-EHM1A 91 North ZENITH ZTS2L15FC-7 1402776-2 ATS-3-GE-X-RAY 91 North ZENITH ZTS2L15EC-7 1402847-2 ATS-1-EC1A 91 North ZENITH ZTS2L15EC-7 1402847-1 ATS-2-EC21 91 North CUMMINS BTPCB-1500816 B15M800254 Lift Station ATS Cemetery ASCO G7AUBB31600C5XM 1457708 WE ATS 3 122 Platform ASCO J07ATBB30150C5XC 1329727 WE ATS-2 122 Sub-basement ASCO J07ATBB30600C5XC 1329726 WE ATS-1 122 Sub-basement ASCO H07ATBB31200C5XC 581676 WE BLD89_ATS-1 88/89 ZENITH ZBTS00B10260F 150163519-10-1 Chiller ATS-1 Bldg 161 CUMMINS BTPCC-A073V586 E23M241483 POWER HOUSE ATS ASCO G07ATBB31600C5XC 2731373-001WE BLD89 ATS-2 88/89 ASCO E0094003100095XC 2443570-001WE DOM BLD 160 ASCO H07ATBA30800C5XC 581679-FP 91 ATS 1 91 South Isolation Panel Equipment Item # Manufacturer Panel Type Serial Model 1 Square D ISO 220525257 2 Square D ISO 2201511637 3 Square D ISO 2201524814 4 Square D ISO

Comparable award range

Historical award values for work matched by the fixed rubric—not an estimate of this opportunity.

No past awards scored highly enough to form a comparable range.

Comparable awards

The match score is decomposed so each comparison can be challenged.

No comparable awards are attached to this notice.

Amendment history

A version is preserved whenever the normalized notice contents change.

VersionNotice typeObservedResponses dueContent hash
1Sources SoughtAug 10, 2026Aug 11, 2026, 6:00 PM UTCac7518f4adba3de7
2Sources SoughtAug 28, 2026Aug 11, 2026, 6:00 PM UTCbf2f4e385c32e097

Record provenance

Field-level lineage for the current opportunity version.

FieldSourceSource as ofParserTransform
agency_nameSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
archive_dateSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
archive_typeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
base_typeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
city_nameSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
contactsSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
descriptionSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
naics_codeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
notice_idSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
notice_typeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
office_citySAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
office_country_codeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
office_nameSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
office_postal_codeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
office_state_codeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
organization_typeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
pop_postal_codeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
pop_street_addressSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
posted_dateSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
psc_codeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
response_deadlineSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
sam_urlSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
solicitation_numberSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
subagency_nameSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
titleSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3
upstream_activeSAM.gov Contract OpportunitiesAug 10, 2026sam_opportunity_snapshot@2026.08.22026.08.3

Sources and method

Figures on this page are computed from public federal award records. Numbers are never estimated or generated; where a figure is withheld, the reason is stated rather than filled in.

  1. 1Notice fields come from the SAM.gov contract opportunities record last seen Aug 29, 2026. SAM.gov remains authoritative.

Note 1 covers the solicitation record. No synthetic FAQ or inferred solicitation value is published.

J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC | — federal contract opportunity · BidBenchmark